PRODUCT DETAILS
22F-D8P7N103 — Entry-Level AC Drive, 480V Three-Phase, 3.7 kW / 5 HP, Fixed Keypad
The 22F-D8P7N103 is a compact, entry-tier variable frequency drive rated at 3.7 kW / 5 HP, accepting 380–480V AC three-phase input and delivering 8.7A output current. It runs V/Hz control with slip compensation, includes a fixed LED keypad with potentiometer for local speed adjustment, and an integral RS-485 (DSI) port for basic serial communication. Feed-through wiring and a Frame B footprint keep the panel space requirement minimal for straightforward speed-control applications.
Specifications
| Parameter | Value |
|---|---|
| Part Number | 22F-D8P7N103 |
| Power Rating | 3.7 kW / 5 HP |
| Input Voltage | 380–480V AC, Three-Phase |
| Output Current | 8.7 A |
| Output Frequency | 0–400 Hz |
| Control Mode | V/Hz with slip compensation |
| Communication | Integral RS-485 (DSI); option cards for EtherNet/IP, DeviceNet |
| HIM | Fixed LED keypad with potentiometer |
| EMC Filter | Not included |
| Enclosure | IP20 / Open Type |
| Frame Size | B |
| Operating Temperature | −10°C to 50°C |
Built for Simple Machine-Level Speed Control
This drive occupies the entry tier of its platform — fixed keypad rather than a removable HIM, V/Hz control without sensorless vector, and no factory-installed EMC filter. These omissions are deliberate cost and complexity tradeoffs aimed squarely at applications that don't need them: basic fan and pump speed control, simple conveyor sections, and OEM machine builds where a straightforward, easy-to-wire drive covers the requirement without paying for capability the application won't use.
The feed-through wiring layout simplifies retrofitting into an existing panel where conduit runs are already established — input and output terminals are arranged for a direct pass-through rather than requiring extensive rerouting. The integral keypad and potentiometer mean the drive is operable straight out of the box for simple speed-only applications, with no separate programming step required before a basic install is running.
FAQ
Q: Can a communication option card be added later for network control?
Yes. The drive accepts option cards for EtherNet/IP, DeviceNet, and other protocols through its expansion port, allowing network connectivity to be added after the initial installation if the application's requirements grow.
Q: Does this drive include an EMC filter for CE compliance?
No, not on this configuration. If CE-compliant EMC filtering is required for the installation, an external filter must be added separately, or a filtered variant of the drive should be specified instead.
Q: Is sensorless vector control available on this drive?
No. This drive supports V/Hz control with slip compensation only. For applications needing better low-speed torque performance, a higher-tier drive platform with sensorless vector capability is the appropriate choice.
Q: What altitude and ambient temperature derating applies?
Full rated output applies up to 1000 m altitude without derating; above that, or above the rated maximum ambient temperature, output current must be reduced according to the drive's standard derating curve.