1746-NI8 New Sealed 1746NI8 SER A SLC 500 Analog Input Module

1746-NI8 New Sealed 1746NI8 SER A SLC 500 Analog Input Module

PRODUCT DETAILS

1746-NI8 — SLC 500 8-Channel Analog Input Module

The 1746-NI8 is an 8-channel analog input module for the SLC 500 control system. Each of the eight channels reads a voltage or current signal from a field instrument — pressure transmitter, flow meter, temperature transmitter, position sensor — and converts it to a 12-bit digital value that the SLC processor reads on each scan cycle. Channel configuration is flexible: voltage modes (0–10V, ±10V, ±5V, ±5V extended, ±10V extended) and current mode (4–20 mA) can be mixed across the eight channels in software.

In installed SLC 500 systems, the 1746-NI8 is one of the most common analog modules in service. It covers the majority of process measurement applications — most industrial transmitters output either 4–20 mA or 0–10V, both of which this module reads directly. For facilities maintaining legacy SLC 500 systems, keeping a spare 1746-NI8 available is standard practice given how frequently analog input modules appear in process control panels.

Specifications

Parameter Value
Part Number 1746-NI8
Platform SLC 500 (1746 series)
Input Channels 8
Input Modes (Voltage) 0–10V, ±10V, ±5V, ±5V extended, ±10V extended
Input Mode (Current) 4–20 mA
Resolution 12-bit (4095 counts across the input range)
Accuracy ±0.25% of full scale @ 25°C
Input Impedance (voltage) ≥ 100 kΩ
Max Loop Resistance (current) 250 Ω
Update Rate ~6 ms per channel (all 8 channels: ~50 ms)
Isolation Not isolated (channels share a common reference)
Backplane Current (5V) 170 mA
Field Power 24V DC external (for 4–20 mA loop supply)
Operating Temperature 0°C to 60°C
Standards UL 508, CE

Where It Gets Used

Eight channels covers most small-to-medium process measurement installations without requiring a second analog input module. A few typical configurations:

  • Four 4–20 mA pressure transmitters plus two 4–20 mA temperature transmitters plus two 0–10V level sensors — a complete instrumentation complement for a small process vessel system in one module slot.
  • A batch process unit where 6–8 flow or temperature measurements feed a PID ladder routine in the SLC processor, with each channel's engineering unit value displayed on an operator station HMI.
  • Legacy HVAC control panels where temperature and pressure measurements from multiple zones connect through the 1746-NI8 for building automation sequence control.

FAQ

Q: Can thermocouple or RTD sensors connect directly to the 1746-NI8?

No. The 1746-NI8 reads standard voltage and current signals — it doesn't have the millivolt-level input sensitivity or cold-junction compensation for thermocouples, or the resistance measurement circuitry for RTDs. Use the 1746-NR4 (RTD) or 1746-NT4 (thermocouple) for direct temperature sensor connections.

Q: What is the 12-bit count value for a 4–20 mA input at 12 mA?

The 4–20 mA range spans 4095 counts across 16 mA. At 12 mA (midpoint), the count value is approximately 2047 — the midscale count. The exact mapping is linear: (input mA − 4) / 16 × 4095.

Q: How is the module configured if RSLogix 500 software isn't available?

The channel configuration (mode, averaging settings) must be done in RSLogix 500 — there's no physical hardware jumper or DIP switch on the module for channel configuration. Without RSLogix 500, the module uses whatever configuration was last stored. For a new installation, RSLogix 500 is required for initial channel setup.

Q: Can I replace a failed 1746-NI8 with a different 8-channel analog input module?

Other analog input modules in the 1746 series may have different I/O image structures, data file formats, or channel configurations. A direct drop-in replacement requires the same catalog number. Substituting a different module type requires verifying I/O image compatibility and potentially updating the RSLogix 500 program.