{"product_id":"6bk1620-0aa00-0aa0-siemens-pn-can-link-gateway-module-6bk16200aa000aa0-new","title":"6BK1620-0AA00-0AA0 Siemens PN\/CAN Link Gateway Module 6BK16200AA000AA0 New","description":"\u003ch2 data-end=\"395\" data-start=\"330\"\u003e\u003cstrong data-end=\"395\" data-start=\"336\"\u003e🔗Siemens PN\/CAN Link Gateway Module – 6BK1620-0AA00-0AA0\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"452\" data-start=\"396\"\u003e\u003cstrong data-end=\"452\" data-start=\"396\"\u003eNew, Genuine Siemens Industrial Communication Module\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"848\" data-start=\"454\"\u003eEnhance mixed-protocol automation networks with the \u003cstrong data-end=\"547\" data-start=\"506\"\u003e\u003cspan class=\"entity-underline hover:entity-accent inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSiemens PN\/CAN Link 6BK1620‑0AA00‑0AA0\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e — a high-performance \u003cstrong data-end=\"604\" data-start=\"569\"\u003ePROFINET to CAN\/CANopen gateway\u003c\/strong\u003e designed for \u003cstrong data-end=\"651\" data-start=\"618\"\u003eindustrial automation systems\u003c\/strong\u003e and reliable device communication. This module bridges Ethernet-based PROFINET IO controllers and field-level CAN or CANopen networks with robust connectivity.\u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-end=\"853\" data-start=\"850\"\u003e\n\u003ch3\u003e📌 Core Technical Parameters\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: Siemens 6BK1620-0AA00-0AA0 (6BK16200AA000AA0)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Industrial PROFINET\/CAN Link Gateway Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Version\u003c\/strong\u003e: V2.0.0 | Support firmware update 📥\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply\u003c\/strong\u003e: DC 24V (20.4~28.8V allowable) | Reverse\/overvoltage\/short-circuit protection ⚡\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 0.09A rated current | 2.2W typical power loss\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces\u003c\/strong\u003e: 2×RJ45 PROFINET ports | 1×9-pin Sub-D CAN port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmission Rate\u003c\/strong\u003e: PROFINET 100 Mbit\/s | CAN 50 kbit\/s ~ 1000 kbit\/s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Capacity\u003c\/strong\u003e: Max 126 CANopen slave nodes | 16 parallel SDO | 512 PDO (Tx\/Rx)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Performance\u003c\/strong\u003e: CAN port 500V AC\/707V DC | PROFINET port 1500V AC\/2250V DC 🛡️\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Size\u003c\/strong\u003e: 70mm(W)×112mm(H)×75mm(D) | Net weight 212g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Mode\u003c\/strong\u003e: DIN rail\/wall\/panel mounting | Any installation position available 🛠️\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -25~60℃ (horizontal) | -25~55℃ (vertical) | Storage: -40~85℃\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Resistance\u003c\/strong\u003e: Max 95% RH (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Grade\u003c\/strong\u003e: IP20 | Suitable for switch cabinet installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: CE, UL, cULus, RCM, KC, EAC | Marine classification society certified 📜\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration Software\u003c\/strong\u003e: STEP 7 TIA Portal (V14 and above) | Plug-and-configure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1780\" data-start=\"1777\"\u003e\n\u003ch3 data-end=\"1813\" data-start=\"1782\"\u003e📊 Technical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"2280\" data-start=\"1815\"\u003e\n\u003cthead data-end=\"1842\" data-start=\"1815\"\u003e\n\u003ctr data-end=\"1842\" data-start=\"1815\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"1825\" data-start=\"1815\"\u003eFeature\u003c\/th\u003e\n\u003cth data-col-size=\"md\" data-end=\"1842\" data-start=\"1825\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"2280\" data-start=\"1871\"\u003e\n\u003ctr data-end=\"1898\" data-start=\"1871\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1879\" data-start=\"1871\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1898\" data-start=\"1879\"\u003eSiemens SIMATIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1929\" data-start=\"1899\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1907\" data-start=\"1899\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1929\" data-start=\"1907\"\u003e6BK1620-0AA00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1967\" data-start=\"1930\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1937\" data-start=\"1930\"\u003eType\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1967\" data-start=\"1937\"\u003ePN\/CAN Link Gateway Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2029\" data-start=\"1968\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1980\" data-start=\"1968\"\u003eProtocols\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2029\" data-start=\"1980\"\u003ePROFINET IO, CAN 2.0A\/B, CANopen (CiA301\/302)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2067\" data-start=\"2030\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2041\" data-start=\"2030\"\u003eEthernet\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2067\" data-start=\"2041\"\u003e2 × RJ45 (10\/100 Mbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2103\" data-start=\"2068\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2084\" data-start=\"2068\"\u003eCAN Interface\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2103\" data-start=\"2084\"\u003e1 × 9-pin D-Sub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2132\" data-start=\"2104\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2121\" data-start=\"2104\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2132\" data-start=\"2121\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2154\" data-start=\"2133\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2146\" data-start=\"2133\"\u003eProtection\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2154\" data-start=\"2146\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2186\" data-start=\"2155\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2166\" data-start=\"2155\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2186\" data-start=\"2166\"\u003eDIN-rail \/ Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2224\" data-start=\"2187\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2204\" data-start=\"2187\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2224\" data-start=\"2204\"\u003e–25 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2280\" data-start=\"2225\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2233\" data-start=\"2225\"\u003eWidth\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2242\" data-start=\"2233\"\u003e~70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-end=\"2285\" data-start=\"2282\"\u003e\n\u003ch3 data-end=\"2314\" data-start=\"2287\"\u003e🏭 Typical Applications\u003c\/h3\u003e\n\u003cp data-end=\"2607\" data-start=\"2316\"\u003e✔ Mixed automation environments requiring PROFINET ↔ CAN\/CANopen connectivity\u003cbr data-end=\"2396\" data-start=\"2393\"\u003e✔ Machine tools, distributed IO networks, and fieldbus integration\u003cbr data-end=\"2465\" data-start=\"2462\"\u003e✔ Process automation linking Siemens PLCs with CAN-based actuators and sensors\u003cbr data-end=\"2546\" data-start=\"2543\"\u003e✔ Legacy upgrades and protocol bridging in industrial systems\u003c\/p\u003e\n\u003chr data-end=\"2612\" data-start=\"2609\"\u003e\n\u003ch3 data-end=\"2629\" data-start=\"2614\"\u003e📦 Included\u003c\/h3\u003e\n\u003cp data-end=\"2790\" data-start=\"2631\"\u003e✔ 1 × Siemens 6BK1620-0AA00-0AA0 Gateway Module\u003cbr data-end=\"2681\" data-start=\"2678\"\u003e✔ Factory packaging (availability may vary by seller)\u003cbr data-end=\"2737\" data-start=\"2734\"\u003e✔ Documentation and mounting instructions if provided\u003c\/p\u003e\n\u003chr data-end=\"2795\" data-start=\"2792\"\u003e\n\u003ch3 data-end=\"2818\" data-start=\"2797\"\u003e📌 Keywords\u003c\/h3\u003e\n\u003cp data-end=\"2984\" data-start=\"2820\"\u003eSiemens 6BK1620-0AA00-0AA0, PN\/CAN Link Gateway, SIMATIC PN\/CAN Link, PROFINET to CAN gateway, Siemens automation communication module, CANopen network integration.\u003c\/p\u003e","brand":"topsdevice","offers":[{"title":"Default Title","offer_id":42765542457405,"sku":null,"price":970.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0635\/6516\/8701\/files\/Siemens6BK1620-0AA00-0AA0_8_2a1b72f0-ed52-4e26-bd20-9ecb2cb4227b.jpg?v=1768442903","url":"https:\/\/topsdevice.com\/products\/6bk1620-0aa00-0aa0-siemens-pn-can-link-gateway-module-6bk16200aa000aa0-new","provider":"topsdevice","version":"1.0","type":"link"}