{"product_id":"al40-04-a-smc-al4004a-filter-lubricator-new-sealed","title":"AL40-04-A SMC AL4004A Filter Lubricator New Sealed","description":"\u003ch2 data-end=\"168\" data-start=\"103\"\u003e\u003cstrong data-end=\"168\" data-start=\"106\"\u003eSMC AL40-04-A Air Filter Lubricator – New \u0026amp; Factory Sealed\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-end=\"194\" data-start=\"170\"\u003e\u003cstrong data-end=\"194\" data-start=\"174\"\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"547\" data-start=\"195\"\u003eThe \u003cstrong data-end=\"234\" data-start=\"199\"\u003eSMC AL40-04-A Filter Lubricator\u003c\/strong\u003e is a high-performance pneumatic air preparation component designed to deliver \u003cstrong data-end=\"349\" data-start=\"313\"\u003eclean, lubricated compressed air\u003c\/strong\u003e for industrial automation systems. As part of SMC’s trusted \u003cstrong data-end=\"423\" data-start=\"410\"\u003eAL Series\u003c\/strong\u003e, this unit ensures stable lubrication, reduced component wear, and extended service life of downstream pneumatic equipment.\u003c\/p\u003e\n\u003cp data-end=\"693\" data-start=\"549\"\u003e\u003cem\u003eThis unit is \u003cstrong data-end=\"589\" data-start=\"562\"\u003ebrand new, original SMC\u003c\/strong\u003e, and \u003cstrong data-end=\"613\" data-start=\"595\"\u003efactory sealed\u003c\/strong\u003e, ideal for OEM replacements, maintenance stock, or new pneumatic system builds.\u003c\/em\u003e\u003c\/p\u003e\n\u003chr data-end=\"698\" data-start=\"695\"\u003e\n\u003ch3 data-end=\"731\" data-start=\"700\"\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003e\u003cstrong data-end=\"731\" data-start=\"704\"\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1363\" data-start=\"732\"\u003e\n\u003cli data-end=\"869\" data-start=\"732\"\u003e\n\u003cp data-end=\"869\" data-start=\"734\"\u003e✅ \u003cstrong data-end=\"775\" data-start=\"736\"\u003eIntegrated Filtration \u0026amp; Lubrication\u003c\/strong\u003e\u003cbr data-end=\"778\" data-start=\"775\"\u003eRemoves contaminants while supplying a consistent oil mist for smooth actuator operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1002\" data-start=\"873\"\u003e\n\u003cp data-end=\"1002\" data-start=\"875\"\u003e✅ \u003cstrong data-end=\"906\" data-start=\"877\"\u003eStable Oil Supply Control\u003c\/strong\u003e\u003cbr data-end=\"909\" data-start=\"906\"\u003eAdjustable oil feed ensures precise lubrication even under fluctuating air flow conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1137\" data-start=\"1004\"\u003e\n\u003cp data-end=\"1137\" data-start=\"1006\"\u003e✅ \u003cstrong data-end=\"1034\" data-start=\"1008\"\u003eReduced Equipment Wear\u003c\/strong\u003e\u003cbr data-end=\"1037\" data-start=\"1034\"\u003eProper lubrication minimizes friction, extending the lifespan of valves, cylinders, and air tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1246\" data-start=\"1139\"\u003e\n\u003cp data-end=\"1246\" data-start=\"1141\"\u003e✅ \u003cstrong data-end=\"1176\" data-start=\"1143\"\u003eIndustrial-Grade Construction\u003c\/strong\u003e\u003cbr data-end=\"1179\" data-start=\"1176\"\u003eBuilt for continuous operation in demanding factory environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1363\" data-start=\"1248\"\u003e\n\u003cp data-end=\"1363\" data-start=\"1250\"\u003e✅ \u003cstrong data-end=\"1279\" data-start=\"1252\"\u003eEasy Maintenance Design\u003c\/strong\u003e\u003cbr data-end=\"1282\" data-start=\"1279\"\u003eTransparent bowl allows quick visual inspection of oil level and contamination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1368\" data-start=\"1365\"\u003e\n\u003ch3 data-end=\"1402\" data-start=\"1370\"\u003e\u003cstrong data-end=\"1402\" data-start=\"1374\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"1918\" data-start=\"1403\"\u003e\n\u003cthead data-end=\"1432\" data-start=\"1403\"\u003e\n\u003ctr data-end=\"1432\" data-start=\"1403\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"1415\" data-start=\"1403\"\u003eParameter\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"1432\" data-start=\"1415\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"1918\" data-start=\"1459\"\u003e\n\u003ctr data-end=\"1485\" data-start=\"1459\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1478\" data-start=\"1459\"\u003e\u003cstrong data-end=\"1477\" data-start=\"1461\"\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1485\" data-start=\"1478\" data-col-size=\"sm\"\u003eSMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1511\" data-start=\"1486\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1498\" data-start=\"1486\"\u003e\u003cstrong data-end=\"1497\" data-start=\"1488\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1511\" data-start=\"1498\" data-col-size=\"sm\"\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003eAL40-04-A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1538\" data-start=\"1512\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1525\" data-start=\"1512\"\u003e\u003cstrong data-end=\"1524\" data-start=\"1514\"\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1538\" data-start=\"1525\" data-col-size=\"sm\"\u003eAL Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1572\" data-start=\"1539\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1555\" data-start=\"1539\"\u003e\u003cstrong data-end=\"1554\" data-start=\"1541\"\u003ePort Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1572\" data-start=\"1555\" data-col-size=\"sm\"\u003e1\/2 inch (04)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1621\" data-start=\"1573\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1604\" data-start=\"1573\"\u003e\u003cstrong data-end=\"1603\" data-start=\"1575\"\u003eOperating Pressure Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1621\" data-start=\"1604\" data-col-size=\"sm\"\u003eUp to 1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1678\" data-start=\"1622\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1659\" data-start=\"1622\"\u003e\u003cstrong data-end=\"1658\" data-start=\"1624\"\u003eRecommended Operating Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1678\" data-start=\"1659\" data-col-size=\"sm\"\u003e0.05 – 0.85 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1726\" data-start=\"1679\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1713\" data-start=\"1679\"\u003e\u003cstrong data-end=\"1712\" data-start=\"1681\"\u003eAmbient \u0026amp; Fluid Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1726\" data-start=\"1713\" data-col-size=\"sm\"\u003e5 to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1768\" data-start=\"1727\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1742\" data-start=\"1727\"\u003e\u003cstrong data-end=\"1741\" data-start=\"1729\"\u003eOil Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1768\" data-start=\"1742\" data-col-size=\"sm\"\u003eISO VG32 (Recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1806\" data-start=\"1769\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1789\" data-start=\"1769\"\u003e\u003cstrong data-end=\"1788\" data-start=\"1771\"\u003eBowl Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1806\" data-start=\"1789\" data-col-size=\"sm\"\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1846\" data-start=\"1807\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1834\" data-start=\"1807\"\u003e\u003cstrong data-end=\"1833\" data-start=\"1809\"\u003eMounting Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1846\" data-start=\"1834\" data-col-size=\"sm\"\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1870\" data-start=\"1847\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1863\" data-start=\"1847\"\u003e\u003cstrong data-end=\"1862\" data-start=\"1849\"\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1870\" data-start=\"1863\" data-col-size=\"sm\"\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1918\" data-start=\"1871\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1887\" data-start=\"1871\"\u003e\u003cstrong data-end=\"1886\" data-start=\"1873\"\u003ePackaging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1918\" data-start=\"1887\" data-col-size=\"sm\"\u003eOriginal SMC factory sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-end=\"1923\" data-start=\"1920\"\u003e\n\u003ch3 data-end=\"1953\" data-start=\"1925\"\u003e\u003cstrong data-end=\"1953\" data-start=\"1929\"\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"2141\" data-start=\"1954\"\u003e\n\u003cli data-end=\"1983\" data-start=\"1954\"\u003e\n\u003cp data-end=\"1983\" data-start=\"1956\"\u003ePneumatic control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2014\" data-start=\"1984\"\u003e\n\u003cp data-end=\"2014\" data-start=\"1986\"\u003eAutomated production lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2050\" data-start=\"2015\"\u003e\n\u003cp data-end=\"2050\" data-start=\"2017\"\u003eAir cylinders \u0026amp; solenoid valves\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2068\" data-start=\"2051\"\u003e\n\u003cp data-end=\"2068\" data-start=\"2053\"\u003eCNC machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2105\" data-start=\"2069\"\u003e\n\u003cp data-end=\"2105\" data-start=\"2071\"\u003ePackaging and assembly equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2141\" data-start=\"2106\"\u003e\n\u003cp data-end=\"2141\" data-start=\"2108\"\u003eIndustrial air tool lubrication\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0635\/6516\/8701\/files\/ChatGPT_Image_2026_1_27_09_30_08.png?v=1769477451\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2146\" data-start=\"2143\"\u003e\n\u003ch2 data-end=\"178\" data-start=\"111\"\u003e📊 \u003cstrong data-end=\"178\" data-start=\"117\"\u003eSMC Air Preparation Series Comparison (AC \/ AF \/ AR \/ AL)\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"1721\" data-start=\"180\"\u003e\n\u003cthead data-end=\"278\" data-start=\"180\"\u003e\n\u003ctr data-end=\"278\" data-start=\"180\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"196\" data-start=\"180\"\u003eItem \/ Series\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"212\" data-start=\"196\"\u003e\u003cstrong data-end=\"211\" data-start=\"198\"\u003eAC Series\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"228\" data-start=\"212\"\u003e\u003cstrong data-end=\"227\" data-start=\"214\"\u003eAF Series\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"md\" data-end=\"244\" data-start=\"228\"\u003e\u003cstrong data-end=\"243\" data-start=\"230\"\u003eAR Series\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"md\" data-end=\"278\" data-start=\"244\"\u003e\u003cstrong data-end=\"276\" data-start=\"246\"\u003eAL Series (e.g. AL40-04-A)\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"1721\" data-start=\"378\"\u003e\n\u003ctr data-end=\"537\" data-start=\"378\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"401\" data-start=\"378\"\u003e\u003cstrong data-end=\"400\" data-start=\"380\"\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"422\" data-start=\"401\" data-col-size=\"sm\"\u003eAir \u003cstrong data-end=\"421\" data-start=\"407\"\u003eFiltration\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd data-end=\"461\" data-start=\"422\" data-col-size=\"sm\"\u003e\u003cstrong data-end=\"460\" data-start=\"424\"\u003eFiltration + Pressure Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"505\" data-start=\"461\" data-col-size=\"md\"\u003e\u003cstrong data-end=\"504\" data-start=\"463\"\u003eFiltration + Regulation + Lubrication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"537\" data-start=\"505\" data-col-size=\"md\"\u003e\u003cstrong data-end=\"535\" data-start=\"507\"\u003eFiltration + Lubrication\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"721\" data-start=\"538\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"557\" data-start=\"538\"\u003e\u003cstrong data-end=\"556\" data-start=\"540\"\u003eMain Purpose\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"584\" data-start=\"557\" data-col-size=\"sm\"\u003eRemove water \u0026amp; particles\u003c\/td\u003e\n\u003ctd data-end=\"624\" data-start=\"584\" data-col-size=\"sm\"\u003eProvide clean and stable air pressure\u003c\/td\u003e\n\u003ctd data-end=\"668\" data-start=\"624\" data-col-size=\"md\"\u003eStable pressure with oil mist lubrication\u003c\/td\u003e\n\u003ctd data-end=\"721\" data-start=\"668\" data-col-size=\"md\"\u003eSupply lubricated air without pressure regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"787\" data-start=\"722\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"756\" data-start=\"722\"\u003e\u003cstrong data-end=\"755\" data-start=\"724\"\u003ePressure Regulator Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"763\" data-start=\"756\" data-col-size=\"sm\"\u003e❌ No\u003c\/td\u003e\n\u003ctd data-end=\"771\" data-start=\"763\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-end=\"779\" data-start=\"771\" data-col-size=\"md\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-end=\"787\" data-start=\"779\" data-col-size=\"md\"\u003e❌ No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"848\" data-start=\"788\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"817\" data-start=\"788\"\u003e\u003cstrong data-end=\"816\" data-start=\"790\"\u003eLubrication (Oil Mist)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"824\" data-start=\"817\" data-col-size=\"sm\"\u003e❌ No\u003c\/td\u003e\n\u003ctd data-end=\"831\" data-start=\"824\" data-col-size=\"sm\"\u003e❌ No\u003c\/td\u003e\n\u003ctd data-end=\"839\" data-start=\"831\" data-col-size=\"md\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-end=\"848\" data-start=\"839\" data-col-size=\"md\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1020\" data-start=\"849\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"888\" data-start=\"849\"\u003e\u003cstrong data-end=\"887\" data-start=\"851\"\u003eRecommended Downstream Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"924\" data-start=\"888\" data-col-size=\"sm\"\u003eValves, cylinders (pre-treatment)\u003c\/td\u003e\n\u003ctd data-end=\"954\" data-start=\"924\" data-col-size=\"sm\"\u003ePrecision pneumatic systems\u003c\/td\u003e\n\u003ctd data-end=\"988\" data-start=\"954\" data-col-size=\"md\"\u003eCylinders, air tools, actuators\u003c\/td\u003e\n\u003ctd data-end=\"1020\" data-start=\"988\" data-col-size=\"md\"\u003eCylinders, valves, air tools\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1075\" data-start=\"1021\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1046\" data-start=\"1021\"\u003e\u003cstrong data-end=\"1045\" data-start=\"1023\"\u003ePressure Stability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1052\" data-start=\"1046\" data-col-size=\"sm\"\u003eLow\u003c\/td\u003e\n\u003ctd data-end=\"1061\" data-start=\"1052\" data-col-size=\"sm\"\u003eMedium\u003c\/td\u003e\n\u003ctd data-end=\"1068\" data-start=\"1061\" data-col-size=\"md\"\u003eHigh\u003c\/td\u003e\n\u003ctd data-end=\"1075\" data-start=\"1068\" data-col-size=\"md\"\u003eLow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1141\" data-start=\"1076\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1102\" data-start=\"1076\"\u003e\u003cstrong data-end=\"1101\" data-start=\"1078\"\u003eOil Feed Adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1108\" data-start=\"1102\" data-col-size=\"sm\"\u003eN\/A\u003c\/td\u003e\n\u003ctd data-end=\"1114\" data-start=\"1108\" data-col-size=\"sm\"\u003eN\/A\u003c\/td\u003e\n\u003ctd data-end=\"1127\" data-start=\"1114\" data-col-size=\"md\"\u003eAdjustable\u003c\/td\u003e\n\u003ctd data-end=\"1141\" data-start=\"1127\" data-col-size=\"md\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1297\" data-start=\"1142\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1172\" data-start=\"1142\"\u003e\u003cstrong data-end=\"1171\" data-start=\"1144\"\u003eAir Quality Improvement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1191\" data-start=\"1172\" data-col-size=\"sm\"\u003eBasic filtration\u003c\/td\u003e\n\u003ctd data-end=\"1223\" data-start=\"1191\" data-col-size=\"sm\"\u003eFiltration + pressure control\u003c\/td\u003e\n\u003ctd data-end=\"1269\" data-start=\"1223\" data-col-size=\"md\"\u003eFiltration + pressure control + lubrication\u003c\/td\u003e\n\u003ctd data-end=\"1297\" data-start=\"1269\" data-col-size=\"md\"\u003eFiltration + lubrication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1354\" data-start=\"1298\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1322\" data-start=\"1298\"\u003e\u003cstrong data-end=\"1321\" data-start=\"1300\"\u003eSystem Complexity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1328\" data-start=\"1322\" data-col-size=\"sm\"\u003eLow\u003c\/td\u003e\n\u003ctd data-end=\"1337\" data-start=\"1328\" data-col-size=\"sm\"\u003eMedium\u003c\/td\u003e\n\u003ctd data-end=\"1344\" data-start=\"1337\" data-col-size=\"md\"\u003eHigh\u003c\/td\u003e\n\u003ctd data-end=\"1354\" data-start=\"1344\" data-col-size=\"md\"\u003eMedium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1486\" data-start=\"1355\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1382\" data-start=\"1355\"\u003e\u003cstrong data-end=\"1381\" data-start=\"1357\"\u003eTypical Installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1411\" data-start=\"1382\" data-col-size=\"sm\"\u003eStandalone or system inlet\u003c\/td\u003e\n\u003ctd data-end=\"1430\" data-start=\"1411\" data-col-size=\"sm\"\u003eAfter air filter\u003c\/td\u003e\n\u003ctd data-end=\"1457\" data-start=\"1430\" data-col-size=\"md\"\u003eIntegrated air prep unit\u003c\/td\u003e\n\u003ctd data-end=\"1486\" data-start=\"1457\" data-col-size=\"md\"\u003eAfter filter or regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1555\" data-start=\"1487\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1514\" data-start=\"1487\"\u003e\u003cstrong data-end=\"1513\" data-start=\"1489\"\u003eCommon Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1524\" data-start=\"1514\" data-col-size=\"sm\"\u003eAC only\u003c\/td\u003e\n\u003ctd data-end=\"1534\" data-start=\"1524\" data-col-size=\"sm\"\u003eAC + AF\u003c\/td\u003e\n\u003ctd data-end=\"1544\" data-start=\"1534\" data-col-size=\"md\"\u003eAC + AR\u003c\/td\u003e\n\u003ctd data-end=\"1555\" data-start=\"1544\" data-col-size=\"md\"\u003eAC + AL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1721\" data-start=\"1556\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1576\" data-start=\"1556\"\u003e\u003cstrong data-end=\"1575\" data-start=\"1558\"\u003ePrimary Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1607\" data-start=\"1576\" data-col-size=\"sm\"\u003eProtect pneumatic components\u003c\/td\u003e\n\u003ctd data-end=\"1638\" data-start=\"1607\" data-col-size=\"sm\"\u003eMaintain stable air pressure\u003c\/td\u003e\n\u003ctd data-end=\"1678\" data-start=\"1638\" data-col-size=\"md\"\u003eReduce wear \u0026amp; ensure smooth operation\u003c\/td\u003e\n\u003ctd data-end=\"1721\" data-start=\"1678\" data-col-size=\"md\"\u003eReduce friction \u0026amp; extend component life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-end=\"1726\" data-start=\"1723\"\u003e\n\u003ch2 data-end=\"1759\" data-start=\"1728\"\u003e🛠 \u003cstrong data-end=\"1759\" data-start=\"1734\"\u003eQuick Selection Guide\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003ch3 data-end=\"1790\" data-start=\"1761\"\u003e✔ Need \u003cstrong data-end=\"1790\" data-start=\"1772\"\u003eclean air only\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"1806\" data-start=\"1791\"\u003e→ \u003cstrong data-end=\"1806\" data-start=\"1793\"\u003eAC Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"1850\" data-start=\"1808\"\u003e✔ Need \u003cstrong data-end=\"1850\" data-start=\"1819\"\u003eclean air + stable pressure\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"1866\" data-start=\"1851\"\u003e→ \u003cstrong data-end=\"1866\" data-start=\"1853\"\u003eAF Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"1928\" data-start=\"1868\"\u003e✔ Need \u003cstrong data-end=\"1928\" data-start=\"1879\"\u003eclean air + pressure regulation + lubrication\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"1944\" data-start=\"1929\"\u003e→ \u003cstrong data-end=\"1944\" data-start=\"1931\"\u003eAR Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"2018\" data-start=\"1946\"\u003e✔ Need \u003cstrong data-end=\"2018\" data-start=\"1957\"\u003eclean air + lubrication (no pressure regulation required)\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"2055\" data-start=\"2019\"\u003e→ \u003cstrong data-end=\"2034\" data-start=\"2021\"\u003eAL Series\u003c\/strong\u003e (e.g. \u003cstrong data-end=\"2054\" data-start=\"2041\"\u003eAL40-04-A\u003c\/strong\u003e)\u003c\/p\u003e\n\u003chr data-end=\"2060\" data-start=\"2057\"\u003e\n\u003ch2 data-end=\"2100\" data-start=\"2062\"\u003e📌 \u003cstrong data-end=\"2100\" data-start=\"2068\"\u003eTypical Application Examples\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"2422\" data-start=\"2102\"\u003e\n\u003cthead data-end=\"2149\" data-start=\"2102\"\u003e\n\u003ctr data-end=\"2149\" data-start=\"2102\"\u003e\n\u003cth data-col-size=\"md\" data-end=\"2125\" data-start=\"2102\"\u003eApplication Scenario\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2149\" data-start=\"2125\"\u003eRecommended Solution\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"2422\" data-start=\"2196\"\u003e\n\u003ctr data-end=\"2227\" data-start=\"2196\"\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2221\" data-start=\"2196\"\u003eGeneral air filtration\u003c\/td\u003e\n\u003ctd data-end=\"2227\" data-start=\"2221\" data-col-size=\"sm\"\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2277\" data-start=\"2228\"\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2266\" data-start=\"2228\"\u003ePrecision pneumatic control systems\u003c\/td\u003e\n\u003ctd data-end=\"2277\" data-start=\"2266\" data-col-size=\"sm\"\u003eAC + AF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2345\" data-start=\"2278\"\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2334\" data-start=\"2278\"\u003ePneumatic cylinders \u0026amp; air tools with pressure control\u003c\/td\u003e\n\u003ctd data-end=\"2345\" data-start=\"2334\" data-col-size=\"sm\"\u003eAC + AR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2422\" data-start=\"2346\"\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2399\" data-start=\"2346\"\u003eLubrication required, pressure controlled upstream\u003c\/td\u003e\n\u003ctd data-end=\"2422\" data-start=\"2399\" data-col-size=\"sm\"\u003eAC + AL (AL40-04-A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-end=\"2427\" data-start=\"2424\"\u003e\n\u003ch2 data-end=\"2462\" data-start=\"2429\"\u003e🔑 \u003cstrong data-end=\"2462\" data-start=\"2435\"\u003eSelection Logic Summary\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cblockquote data-end=\"2637\" data-start=\"2463\"\u003e\n\u003cp data-end=\"2637\" data-start=\"2465\"\u003e\u003cstrong data-end=\"2537\" data-start=\"2465\"\u003eFiltration first, pressure regulation second, lubrication as needed.\u003c\/strong\u003e\u003cbr data-end=\"2540\" data-start=\"2537\"\u003eAir preparation systems typically follow this sequence:\u003cbr data-end=\"2600\" data-start=\"2597\"\u003e\u003cstrong data-end=\"2637\" data-start=\"2602\"\u003eFilter → Regulator → Lubricator\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch3 data-end=\"2181\" data-start=\"2148\"\u003e\u003cstrong data-end=\"2181\" data-start=\"2152\"\u003eWhy Choose SMC AL40-04-A?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"2460\" data-start=\"2182\"\u003eSMC is a \u003cstrong data-end=\"2232\" data-start=\"2191\"\u003eglobal leader in pneumatic technology\u003c\/strong\u003e, known for precision engineering and long-term reliability. The \u003cstrong data-end=\"2310\" data-start=\"2297\"\u003eAL40-04-A\u003c\/strong\u003e is a proven solution for maintaining air quality and lubrication consistency, helping reduce downtime and maintenance costs in industrial operations.\u003c\/p\u003e\n\u003chr data-end=\"2465\" data-start=\"2462\"\u003e\n\u003ch3 data-end=\"2515\" data-start=\"2467\"\u003e\u003cstrong data-end=\"2515\" data-start=\"2471\"\u003eKeywords\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"2668\" data-start=\"2516\"\u003eSMC AL40-04-A, SMC Filter Lubricator, AL40-04-A New Sealed, Pneumatic Air Lubricator, SMC Air Preparation Unit, Industrial Air Lubricator, SMC AL Series\u003c\/p\u003e","brand":"topsdevice","offers":[{"title":"Default Title","offer_id":42779259076669,"sku":null,"price":28.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0635\/6516\/8701\/files\/AL40-04-A_8_7a228e6d-352b-424e-8290-cc97a688329d.jpg?v=1768269212","url":"https:\/\/topsdevice.com\/products\/al40-04-a-smc-al4004a-filter-lubricator-new-sealed","provider":"topsdevice","version":"1.0","type":"link"}