{"product_id":"bsp00yk-new-in-box-bsp00yk-balluff-pressure-sensor","title":"BSP00YK New In Box BSP00YK Balluff Pressure Sensor","description":"\u003ch2 class=\"text-text-100 mt-3 -mb-1 text-[1.375rem] font-bold\"\u003eBalluff BSP00YK | Digital Pressure Sensor with Display | 0–600 bar · IO-Link 1.1 · New In Box\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e BSP00YK | \u003cstrong\u003eFull Type Code:\u003c\/strong\u003e BSP B600-EV009-P00S2B-S4 | \u003cstrong\u003eBrand:\u003c\/strong\u003e Balluff | \u003cstrong\u003eReplaces:\u003c\/strong\u003e BSP000R | \u003cstrong\u003eCondition:\u003c\/strong\u003e New In Box\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch2 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003eWhy This Sensor?\u003c\/h2\u003e\n\u003cblockquote class=\"ml-2 border-l-4 border-border-300\/10 pl-4 text-text-300\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e600 bar range. IO-Link 1.1 communication. Rotatable LED display. Dual switching outputs. Stainless steel body. ±0.5% accuracy.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe \u003cstrong\u003eBalluff BSP00YK\u003c\/strong\u003e is a high-range digital pressure sensor built for industrial hydraulic systems, high-pressure process lines, and demanding automation environments where both precision and ruggedness are non-negotiable. At its core is a stainless steel measuring cell, a configurable IO-Link 1.1 interface, selectable analog output, and two independently switchable PNP\/NPN outputs — all in a compact G1\/4\" cylindrical body with a rotatable LED display that can be read from any installation angle.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch2 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eBSP00YK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eFull Type Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eBSP B600-EV009-P00S2B-S4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eBalluff GmbH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eBSP — Digital Pressure Sensor with Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e0 … 600 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eMeasuring Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eRelative (gauge) pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e±0.5 % FSO BFSL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eOverload Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e1,000 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eBurst Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e1,570 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e18 … 30 V DC (24 V DC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eIO-Link 1.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e4…20 mA \/ 0…10 V — selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eSwitching Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e2 × PNP\/NPN, NO\/NC switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eM12 × 1, 4-pin male connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eProcess Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eG 1\/4\" (DIN 3852)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eProcess Connection Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e1.4301 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eGasket Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eFKM (Fluoroelastomer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e1.4301 stainless steel + HDPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eMedia Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e−40 … +125 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e−40 … +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eIP67 (when threaded in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eLED, rotatable 330°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eReplaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eBSP000R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eUL, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eNew In Box — Original Balluff OEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003ePart Number Decoder: What Does BSP B600-EV009-P00S2B-S4 Mean?\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eRather than memorising a type code, understanding its structure helps you quickly verify you have the correct variant:\u003c\/p\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eBSP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eBalluff pressure sensor family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eB600\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eMeasuring range: 0–600 bar (relative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eEV009\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eElectronic version \/ sensor cell variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eP00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eProcess connection: G 1\/4\" (DIN 3852), stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eS2B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eOutput configuration: IO-Link + 2× switching + analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eS4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eConnection: M12 × 1, 4-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eIf you need a different pressure range but the same output and connection configuration, simply change the range segment — for example, BSP00Y4 covers 0–10 bar with the identical interface.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch2 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003eThree Output Modes in One Device\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eOne of the BSP00YK's most practical features is its \u003cstrong\u003eoutput flexibility\u003c\/strong\u003e. A single sensor covers three different signal architectures:\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003e① Analog Output — 4…20 mA or 0…10 V\u003c\/strong\u003e The analog output provides a continuously proportional signal across the 0–600 bar range. The 4…20 mA current loop variant is preferred for long cable runs (immune to resistive voltage drop) and for process control systems with 4…20 mA analog input cards. The 0…10 V option suits PLC analog inputs with voltage-type inputs. The selection is made via IO-Link parametrisation or local button configuration.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003e② Two Switching Outputs (PNP \/ NPN, NO \/ NC)\u003c\/strong\u003e Two independent transistor switching outputs allow the sensor to trigger two separate threshold events — for example, a low-pressure warning at 50 bar and a high-pressure trip at 550 bar. Each output can be independently configured as PNP or NPN and as normally open or normally closed, allowing integration with either sourcing or sinking PLC input modules without additional signal conversion hardware.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003e③ IO-Link 1.1 Digital Communication\u003c\/strong\u003e IO-Link provides full bidirectional digital communication between the sensor and an IO-Link master. Over IO-Link, the sensor transmits the measured pressure value as a 16-bit digital word (eliminating analog conversion error), and the controller can remotely read diagnostics, change switching thresholds, adjust output configuration, and write parameter sets — all without physical access to the sensor. This is particularly valuable in installations where the sensor is mounted in an inaccessible location or where rapid changeover between product recipes requires repraming of pressure thresholds.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch2 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003eWhere Is the BSP00YK Deployed?\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eHydraulic Power Units \u0026amp; Press Lines\u003c\/strong\u003e With a 600 bar range and 1,000 bar overload rating, this sensor is built for high-pressure hydraulic circuits on metal-forming presses, injection moulding machines, and forging equipment. The FKM gasket and stainless steel process connection handle hydraulic oil and water-glycol fluids.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eHigh-Pressure Water Systems\u003c\/strong\u003e Waterjet cutting systems, industrial cleaning equipment, and high-pressure water injection systems often operate in the 200–600 bar range — exactly where this sensor's range is optimised.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003ePlastic Injection Moulding\u003c\/strong\u003e Mould cavity pressure monitoring and hydraulic clamp pressure monitoring on injection moulding machines, where precise pressure control directly impacts part quality and cycle consistency.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eLeak Testing Equipment\u003c\/strong\u003e Pressure decay testing of components and assemblies at elevated pressures, where stable, accurate readings and switchable alarm outputs are essential.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eIndustrial Automation with IO-Link Networks\u003c\/strong\u003e Any application where IO-Link architecture is used for distributed sensor parametrisation, predictive maintenance data collection, or centralised condition monitoring — the BSP00YK integrates directly into any IO-Link 1.1 master port.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch2 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003eThe Rotatable Display — A Practical Detail That Matters\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe M12 connection is independently rotatable lautomation\u003cspan data-state=\"closed\" class=\"inline-flex\"\u003e\u003c\/span\u003e, and the LED display housing can be rotated up to 330° relative to the process connection — meaning once the sensor is screwed into the hydraulic port, the display can be oriented to face the operator regardless of the installation angle. On a press line where sensors are mounted at 45° angles inside the machine frame, this eliminates the need for mirror reading or contorted viewing angles. The display shows the current pressure value in the configured engineering unit and also indicates the switching output status.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch2 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003eBSP00YK vs Comparable \u003ca rel=\"noopener\" title=\"Test Balluff pressure sensor\" href=\"https:\/\/www.youtube.com\/watch?v=g7RvtjHKH2M\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eBalluff Pressure Sensor\u003c\/span\u003e\u003c\/a\u003e Variants\u003c\/h2\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eModel\u003c\/th\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eRange\u003c\/th\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eKey Difference\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eBSP00YK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e0–600 bar\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eHigh-range hydraulic\/process applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eBSP00Y4\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e0–10 bar\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eLow-pressure pneumatic\/fluid systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eBSP00YR\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e−1…+2 bar\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eVacuum and low positive pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eBSP00JK\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e0–10 bar\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eNo display, compact, analog-only output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eBSP000R\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e0–600 bar\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003ePredecessor — BSP00YK is the direct replacement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cblockquote class=\"ml-2 border-l-4 border-border-300\/10 pl-4 text-text-300\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e If you are currently running BSP000R sensors and need replacements, the BSP00YK is the official Balluff successor and is a direct functional replacement with enhanced IO-Link 1.1 capability.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch2 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003eOEM vs Generic Pressure Sensors — The Case for Balluff\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eHigh-pressure sensors are not a component category where generic substitution is advisable. At 600 bar system pressure, a seal failure or housing fracture is a safety incident, not an inconvenience.\u003c\/p\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eAttribute\u003c\/th\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eBalluff BSP00YK (OEM)\u003c\/th\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eGeneric \/ Unbranded\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003ePressure range verified\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e0–600 bar, factory calibrated\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eOften uncalibrated or estimated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eOverload rating tested\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e1,000 bar\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eUnspecified or unavailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eBurst pressure rated\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e1,570 bar\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eNot documented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eAccuracy class\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e±0.5% FSO BFSL, VDMA standard\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eIO-Link 1.1 certified\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e✅\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e❌ Rarely\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eUL \/ CE approval\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e✅\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e❌ Usually none\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eMedia compatibility verified\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eFKM gasket, 1.4301 SS\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eUnknown materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eReplacement traceability\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eDirect replacement for BSP000R\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eNo documented lineage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch2 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003eOrdering \u0026amp; Delivery\u003c\/h2\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e✅ \u003cstrong\u003eNew In Box\u003c\/strong\u003e — genuine Balluff OEM, factory sealed, never installed\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e✅ \u003cstrong\u003eIn Stock\u003c\/strong\u003e — dispatches within 1–3 working days\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e✅ \u003cstrong\u003eGlobal Shipping\u003c\/strong\u003e — DHL \/ FedEx \/ UPS tracked delivery worldwide\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e✅ \u003cstrong\u003eVolume pricing available\u003c\/strong\u003e — contact us for multi-unit orders\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e✅ \u003cstrong\u003e15+ years industrial automation supply\u003c\/strong\u003e expertise\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch2 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ1: What does BSP00YK measure — absolute or relative (gauge) pressure?\u003c\/strong\u003e The BSP00YK measures \u003cstrong\u003erelative (gauge) pressure\u003c\/strong\u003e, meaning it measures pressure relative to ambient atmospheric pressure. At atmospheric pressure, the output reads zero. Absolute pressure sensors measure relative to a perfect vacuum (zero reference). For most industrial hydraulic and pneumatic applications, gauge pressure is the correct measurement — it tells you the actual working pressure above atmospheric, which is the value that drives system behaviour.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ2: What is the difference between ±0.5% FSO BFSL accuracy and other accuracy specifications?\u003c\/strong\u003e FSO means Full Scale Output — the accuracy figure applies across the entire 0–600 bar range. BFSL means Best Fit Straight Line — the error is calculated after fitting the ideal straight line through the measured data, which removes offset and gain error and represents only the nonlinearity component. This is a favourable but standard method of specifying sensor accuracy in the industrial sensor industry. The practical implication: at 600 bar full scale, ±0.5% FSO equals ±3 bar of maximum error across the range.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ3: What is IO-Link 1.1, and does my system need to support it?\u003c\/strong\u003e IO-Link is a point-to-point serial communication standard (IEC 61131-9) for sensors and actuators. The sensor connects to an IO-Link master module (available from Balluff, Siemens, Turck, Pepperl+Fuchs, and others) which is typically installed in a PLC IO rack or field-mounted junction box. If your system does not have an IO-Link master, the BSP00YK can still be used in \u003cstrong\u003estandard I\/O mode\u003c\/strong\u003e — the switching outputs and analog output function normally without IO-Link communication. IO-Link adds remote parametrisation and diagnostics on top of the standard signal outputs; it does not replace them.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ4: Can the switching thresholds be set without IO-Link — using the buttons on the sensor?\u003c\/strong\u003e Yes. The BSP00YK has local push-button configuration accessible via the sensor's front panel. Switching point thresholds (SP1, SP2), hysteresis, output polarity (NO\/NC), and analog output type (4–20 mA or 0–10 V) can all be set locally without an IO-Link master or configuration tool. Parametrisation follows the VDMA standard interface, which is consistent across Balluff's BSP series and familiar to engineers working with other VDMA-compliant pressure sensors.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ5: What fluids is the BSP00YK compatible with?\u003c\/strong\u003e The wetted materials are \u003cstrong\u003e1.4301 (304) stainless steel\u003c\/strong\u003e for the process connection and \u003cstrong\u003eFKM (Fluoroelastomer \/ Viton)\u003c\/strong\u003e for the gasket. This combination is compatible with mineral hydraulic oil, water-glycol hydraulic fluid, synthetic esters, clean water, mild acids, and many industrial process fluids. It is not suitable for strongly oxidising acids, concentrated alkalis, or fluids that attack stainless steel or FKM. For aggressive media applications, consult Balluff's chemical compatibility data before specifying.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ6: What is the difference between the BSP00YK and its predecessor BSP000R?\u003c\/strong\u003e The BSP00YK replaces the BSP000R lautomation as the current active catalogue part. The BSP00YK adds \u003cstrong\u003eIO-Link 1.1\u003c\/strong\u003e communication capability (the BSP000R had IO-Link 1.0 or no IO-Link depending on variant), updated electronics with the EV009 generation sensor cell, and the independently rotatable M12 connector. Mechanically and electrically, the BSP00YK is a drop-in replacement for the BSP000R — same G1\/4\" process connection, same M12 connector, same output signal types.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ7: What does the overload pressure of 1,000 bar mean in practice?\u003c\/strong\u003e Overload pressure is the maximum pressure the sensor can withstand — including pressure spikes — without permanent damage to the measuring cell or loss of calibration accuracy. The BSP00YK will survive pressure peaks up to 1,000 bar without recalibration being required. The burst pressure of 1,570 bar is the pressure at which the housing may fail mechanically — this is a safety margin figure, not an operating limit. For systems with known pressure spikes (e.g., hydraulic hammer from valve closure), the 1,000 bar overload rating provides a 1.67× safety factor over the 600 bar measuring range.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ8: The sensor is rated IP67. Can it be submerged in fluid during operation?\u003c\/strong\u003e IP67 means the sensor is protected against temporary immersion in water up to 1 metre depth for 30 minutes. For standard industrial environments — splashing, spray, washdown — IP67 provides robust protection when the M12 connector is fully mated and tightened. Note that the IP67 rating applies when the sensor is \u003cstrong\u003ethreaded into the process connection\u003c\/strong\u003e and the M12 connector is connected. An unmated sensor with an open M12 socket is not rated IP67 at the connector entry.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ9: What cable or connector do I need to connect the BSP00YK?\u003c\/strong\u003e The sensor has an \u003cstrong\u003eM12 × 1, 4-pin male connector\u003c\/strong\u003e on the sensor body. You need a mating \u003cstrong\u003eM12 female, 4-pin straight or angled cable assembly\u003c\/strong\u003e. Standard pin assignment: Pin 1 = +V supply (brown), Pin 3 = 0V \/ GND (blue), Pin 4 = Output 1 \/ IO-Link C\/Q (black), Pin 2 = Output 2 (white). Balluff and many third-party suppliers offer pre-assembled M12 cables in various lengths. For IO-Link operation, use an unshielded 3-wire or 4-wire cable per the IO-Link standard; maximum cable length per IO-Link port is 20 metres.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ10: Is this sensor suitable for food and beverage or pharmaceutical applications?\u003c\/strong\u003e The BSP00YK with G1\/4\" stainless steel connection and FKM gasket is used in many industrial food processing applications — it is not a hygienic design sensor (no Tri-Clamp or EHEDG\/FDA-compliant wetted materials are specified for this variant). For food-contact or pharmaceutical applications requiring hygienic process connections and FDA-approved materials, Balluff offers specific hygienic variants within the BSP series. The BSP00YK is appropriate for non-product-contact measurement points such as hydraulic circuits, cooling water, and utility systems in food factories.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ11: Can I order multiple units, and is volume pricing available?\u003c\/strong\u003e Yes. We regularly supply bulk orders for maintenance spare parts programmes, new machine builds, and system integration projects. Contact us with your required quantity and delivery destination for a prompt quotation. For urgent requirements, express shipment via DHL is available on request.\u003c\/p\u003e","brand":"topsdevice","offers":[{"title":"Default Title","offer_id":42782363320381,"sku":null,"price":332.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0635\/6516\/8701\/files\/BSP00YKBSPB600-EV009-P00S2B-S4.jpg?v=1773719568","url":"https:\/\/topsdevice.com\/products\/bsp00yk-new-in-box-bsp00yk-balluff-pressure-sensor","provider":"topsdevice","version":"1.0","type":"link"}