{"product_id":"cqm1-od212-genuine-cqm1od212-omron-module-new-in-box","title":"CQM1-OD212 Genuine CQM1OD212 Omron Module New In Box","description":"\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003ch2 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eOmron CQM1-OD212 Digital Output Module — 16-Point NPN | Genuine New In Box\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe \u003cstrong\u003eOmron CQM1-OD212\u003c\/strong\u003e is a 16-point NPN transistor digital output module for the \u003cstrong\u003eOmron CQM1 series PLC platform\u003c\/strong\u003e. Rated at DC 12–24V with a response time of ≤1ms and photocoupler isolation on every channel, it delivers the fast, reliable switching that production lines, packaging machines, and automated assembly systems depend on.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003e100% genuine Omron product. Factory sealed. Ready for immediate worldwide shipment.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003ch3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eThe CQM1-OD212 at a Glance\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThree numbers define why engineers reach for this module:\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003e16\u003c\/strong\u003e output points — the ideal count for mid-size control panels without unnecessary module slots\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003e0.1A\u003c\/strong\u003e per point — sufficient for standard discrete loads: solenoid valves, indicator lamps, relay coils, and small actuators\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003e≤1ms\u003c\/strong\u003e response time — fast enough for high-frequency switching sequences in packaging and assembly applications\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003ch3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eFull Technical Specifications\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eModel\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eCQM1-OD212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eCompatible PLC\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eOmron CQM1 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eOutput Type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eTransistor — NPN (sinking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eDC 12–24V (±10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eMax Output Current\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e0.1A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eIsolation Method\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003ePhotocoupler isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eResponse Time (ON)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e≤0.1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eResponse Time (OFF)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e≤0.4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eLeakage Current\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e≤0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eMounting\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eCQM1 PLC rack \/ expansion slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eOrigin\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eCondition\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eGenuine New \/ Factory Sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cblockquote class=\"ml-2 border-l-4 border-border-300\/10 pl-4 text-text-300\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e💡 \u003cstrong\u003eWiring note:\u003c\/strong\u003e The CQM1-OD212 uses \u003cstrong\u003eNPN (sinking) transistor outputs\u003c\/strong\u003e. This means the load is connected between the output terminal and the positive supply, with the output pulling to common (0V) when active. If your field devices require PNP (sourcing) logic, the CQM1-OD215 is the correct alternative.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003ch3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eUnderstanding the CQM1-OD212 Model Code\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cdiv class=\"relative group\/copy bg-bg-000\/50 border-0.5 border-border-400 rounded-lg\"\u003e\n\u003cdiv class=\"sticky opacity-0 group-hover\/copy:opacity-100 top-2 py-2 h-12 w-0 float-right\"\u003e\n\u003cdiv class=\"absolute right-0 h-8 px-2 items-center inline-flex z-10\"\u003e\n\u003cdiv class=\"relative\"\u003e\n\u003cdiv class=\"transition-all opacity-100 scale-100\"\u003e\u003csvg width=\"20\" height=\"20\" viewbox=\"0 0 20 20\" fill=\"currentColor\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"transition-all opacity-100 scale-100\" aria-hidden=\"true\"\u003e\u003cpath d=\"M12.5 3C13.3284 3 14 3.67157 14 4.5V6H15.5C16.3284 6 17 6.67157 17 7.5V15.5C17 16.3284 16.3284 17 15.5 17H7.5C6.67157 17 6 16.3284 6 15.5V14H4.5C3.67157 14 3 13.3284 3 12.5V4.5C3 3.67157 3.67157 3 4.5 3H12.5ZM14 12.5C14 13.3284 13.3284 14 12.5 14H7V15.5C7 15.7761 7.22386 16 7.5 16H15.5C15.7761 16 16 15.7761 16 15.5V7.5C16 7.22386 15.7761 7 15.5 7H14V12.5ZM4.5 4C4.22386 4 4 4.22386 4 4.5V12.5C4 12.7761 4.22386 13 4.5 13H12.5C12.7761 13 13 12.7761 13 12.5V4.5C13 4.22386 12.7761 4 12.5 4H4.5Z\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv class=\"absolute inset-0 flex items-center justify-center\"\u003e\n\u003cdiv class=\"transition-all opacity-0 scale-50\"\u003e\u003csvg width=\"20\" height=\"20\" viewbox=\"0 0 20 20\" fill=\"currentColor\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"transition-all opacity-0 scale-50\" aria-hidden=\"true\"\u003e\u003cpath d=\"M15.1883 5.10908C15.3699 4.96398 15.6346 4.96153 15.8202 5.11592C16.0056 5.27067 16.0504 5.53125 15.9403 5.73605L15.8836 5.82003L8.38354 14.8202C8.29361 14.9279 8.16242 14.9925 8.02221 14.9989C7.88203 15.0051 7.74545 14.9526 7.64622 14.8534L4.14617 11.3533L4.08172 11.2752C3.95384 11.0811 3.97542 10.817 4.14617 10.6463C4.31693 10.4755 4.58105 10.4539 4.77509 10.5818L4.85321 10.6463L7.96556 13.7586L15.1161 5.1794L15.1883 5.10908Z\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"overflow-x-auto\"\u003e\n\u003cpre class=\"code-block__code !my-0 !rounded-lg !text-sm !leading-relaxed p-3.5\"\u003e\u003ccode\u003e\u003cspan\u003eCQM1  -  OD  -  212\n\u003c\/span\u003e\u003cspan\u003e│        │     └─ 212: 16-point NPN transistor output, standard current\n\u003c\/span\u003e\u003cspan\u003e│        └─────────  OD: Output module, DC transistor type\n\u003c\/span\u003e\u003cspan\u003e└────────────────────  CQM1: Omron CQM1 PLC product family\u003c\/span\u003e\u003c\/code\u003e\u003c\/pre\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThis naming convention makes it straightforward to identify the correct replacement — if your failed module is marked CQM1-OD212, the part on this page is your exact drop-in replacement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003ch3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eCQM1 Output Module Comparison — Which One Do You Need?\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\"\u003eModel\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\"\u003eOutput Points\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\"\u003eOutput Type\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\"\u003eMax Current\/Point\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\"\u003eBest For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eCQM1-OD212\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003e16\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003eNPN (sinking)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u003cstrong\u003e0.1A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e⭐ General-purpose panels, standard discrete loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eCQM1-OD213\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e32\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eNPN (sinking)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e0.1A\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eHigh I\/O density, machines with many discrete outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eCQM1-OD215\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e8\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003ePNP (sourcing)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e1.0A\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eHeavy loads — solenoids, actuators, higher current devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eHow to choose in 3 steps:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-decimal flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eCount your output signals\u003c\/strong\u003e → 16 points covers most mid-size control panels\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eCheck your wiring logic\u003c\/strong\u003e → NPN (sinking) for OD212\/OD213 | PNP (sourcing) for OD215\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eCheck your load current\u003c\/strong\u003e → Standard loads (≤0.1A): OD212 or OD213 | Higher current (≤1A): OD215\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003ch3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eWhere the CQM1-OD212 Is Used\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe CQM1-OD212 controls discrete output signals across a wide range of industrial machinery:\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003ePackaging machines\u003c\/strong\u003e — carton folding, sealing, and labelling actuator control\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eAssembly lines\u003c\/strong\u003e — part clamping, indexing, and reject gate activation\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eConveyor systems\u003c\/strong\u003e — belt drive enable\/disable and diverter gate control\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eMachine tools\u003c\/strong\u003e — coolant pump control, chuck actuation, tool change sequences\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003ePanel builders \u0026amp; OEM integrators\u003c\/strong\u003e — standard output module for CQM1-based control cabinets\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eMaintenance replacement\u003c\/strong\u003e — direct swap for failed CQM1-OD212 units in existing installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003ch3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eShipping \u0026amp; Quality Guarantee\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e🔒 100% original Omron product — factory sealed\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e🔍 Pre-shipment inspection on every unit\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e📦 Original factory box with manufacturer label and serial identification\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e🌍 Worldwide express shipping available\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e⚡ In-stock orders dispatched within 1–2 business days\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003ch3 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003eFAQ — Omron CQM1-OD212 Output Module\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ1: Is the CQM1-OD212 a genuine Omron product?\u003c\/strong\u003e Yes. Every unit we supply is a 100% original Omron CQM1-OD212, factory new and sealed in the original box. We do not supply aftermarket or remanufactured modules. Genuine Omron modules ensure full firmware compatibility and rated electrical performance in your CQM1 PLC system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ2: Which PLC systems is the CQM1-OD212 compatible with?\u003c\/strong\u003e The CQM1-OD212 is designed exclusively for the \u003cstrong\u003eOmron CQM1 series PLC\u003c\/strong\u003e platform. It is not compatible with other Omron PLC families such as the CJ, CS, or CP series. Always confirm your existing PLC backplane and CPU model is CQM1 before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ3: What is the difference between NPN and PNP output, and which does the CQM1-OD212 use?\u003c\/strong\u003e The CQM1-OD212 uses \u003cstrong\u003eNPN (sinking) transistor outputs\u003c\/strong\u003e. In NPN wiring, the output pulls the load line to 0V (common) when active — the load connects between the output terminal and the positive DC supply. If your field devices require a \u003cstrong\u003ePNP (sourcing)\u003c\/strong\u003e output, you need the \u003cstrong\u003eCQM1-OD215\u003c\/strong\u003e instead. Mixing NPN and PNP modules without rewiring will cause outputs not to function correctly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ4: Can the CQM1-OD212 control solenoid valves directly?\u003c\/strong\u003e It depends on the solenoid's current draw. The CQM1-OD212 is rated at \u003cstrong\u003e0.1A per output point\u003c\/strong\u003e. Most small pilot solenoid valves (24V DC) draw 0.06–0.1A and are compatible. Larger solenoids exceeding 0.1A will require an interposing relay or should be driven via the higher-current \u003cstrong\u003eCQM1-OD215\u003c\/strong\u003e (rated 1.0A per point).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ5: Is the CQM1-OD212 a direct plug-in replacement for a failed module?\u003c\/strong\u003e Yes — it is a direct rack-mount replacement for any existing CQM1-OD212 installation. No PLC configuration or parameter changes are required; simply slot it into the same rack position. Ensure the PLC is powered down before swapping modules as a standard safety precaution.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ6: The CQM1 is an older PLC series — is this module still available?\u003c\/strong\u003e Yes, we maintain stock of genuine CQM1-series modules to support the large installed base of CQM1 PLCs still running in factories worldwide. While Omron has transitioned to newer platforms, the CQM1 remains in active use and we can supply genuine replacement modules with fast worldwide shipping.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ7: Do you offer bulk pricing for spare parts stocking?\u003c\/strong\u003e Yes. Many maintenance teams and panel builders stock multiples of the CQM1-OD212 as a critical spare. Contact us via WhatsApp or the Enquiry button with your required quantities for volume pricing and availability confirmation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cem\u003eNeed help confirming CQM1 module compatibility or identifying the right output module for your application? Our technical team is ready to assist.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cem\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0635\/6516\/8701\/files\/CQM1-OD212_2_800x800_4e95d3d7-c738-4c36-bb25-b0e018d75d5b.jpg?v=1772766756\" alt=\"\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"topsdevice","offers":[{"title":"Default Title","offer_id":42782324490301,"sku":null,"price":95.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0635\/6516\/8701\/files\/CQM1-OD212_Omron.jpg?v=1773718043","url":"https:\/\/topsdevice.com\/products\/cqm1-od212-genuine-cqm1od212-omron-module-new-in-box","provider":"topsdevice","version":"1.0","type":"link"}