{"product_id":"d2-12tr-plc-direct-koyo-relay-output-module-d212tr-new-in-box","title":"D2-12TR PLC Direct Koyo Relay Output Module D212TR New In Box","description":"\u003ch3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eProduct Description\u003c\/h3\u003e\n\u003ch3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eD2-12TR — Koyo DirectLOGIC 205 Relay Output Module\u003c\/h3\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eIf you're building or maintaining a DirectLOGIC 205 PLC system, the \u003cstrong\u003eD2-12TR\u003c\/strong\u003e is one of the most versatile output modules in the DL205 lineup. With 12 relay output points, broad voltage compatibility, and a removable terminal block that makes field installation genuinely straightforward, it earns its place in control panels across manufacturing, material handling, and process automation environments alike.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch4 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eFull Technical Specifications\u003c\/h4\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eD2-12TR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eCompatible Platform\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eDirectLOGIC DL205 \/ Do-more PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eAutomationDirect \/ Koyo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eOutput Points\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003ePoints Consumed\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e16 (4 unused)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eOutput Type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eRelay, Form A (SPST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e5–30 VDC \/ 5–240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003ePeak Voltage\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e30 VDC \/ 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eAC Frequency\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e47–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eCommons per Module\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e2 (6 points per common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eMax Load Current\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e1.5A per point \/ 3A per common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eMinimum Load Current\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e5mA @ 5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eMax Leakage Current\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e0.1 mA @ 265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eResponse Time (OFF→ON)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eResponse Time (ON→OFF)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eBase Power Required\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e5VDC @ 450 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eTerminal Block\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eRemovable (D2-16IOCON)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eStatus Indicator\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eLogic side LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eFuses\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e(2) 4A slow-blow, replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e4.6 oz. (130g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch4 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eWhy Relay Outputs — And Why This Module\u003c\/h4\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eTransistor outputs are faster, but relay outputs remain the preferred choice for many real-world control tasks. They switch both AC and DC loads without requiring separate power supplies for each load type. More importantly, they provide true electrical isolation between the PLC logic and the field device — a practical advantage when controlling solenoid valves, contactors, indicator lamps, or small motors.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe D2-12TR covers an unusually wide voltage window: \u003cstrong\u003e5V to 240V AC and 5V to 30V DC\u003c\/strong\u003e. That flexibility means a single module type can handle a mix of 24VDC sensors, 110VAC coils, and 220VAC devices on the same rack, reducing the number of different spare parts you need to keep on hand.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch4 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eBuilt for Real Maintenance Conditions\u003c\/h4\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eOne of the less-discussed advantages of the D2-12TR is its \u003cstrong\u003eremovable terminal block\u003c\/strong\u003e. In practice, this makes a meaningful difference during installation and replacement — you can pre-wire the terminal block off the module, then snap it in when the module is seated. No need to disconnect field wiring to swap out a failed module during a plant shutdown. That kind of design consideration reflects the practical engineering behind the DirectLOGIC 205 platform.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe two \u003cstrong\u003ereplaceable 4A slow-blow fuses\u003c\/strong\u003e add another layer of protection, allowing field personnel to restore operation after an overcurrent event without replacing the entire module.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch4 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eLoad Types \u0026amp; Contact Life Reference\u003c\/h4\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eLoad Type\u003c\/th\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eVoltage\u003c\/th\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eResistive\u003c\/th\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eInductive\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eDC Loads\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e24VDC\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e1A \/ 500k cycles\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e1A \/ 100k cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eDC Loads\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e110VDC\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e1A \/ 500k cycles\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e1A \/ 200k cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eAC Loads\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e220VAC\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e1A \/ 350k cycles\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e1A \/ 100k cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch4 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eTypical Applications\u003c\/h4\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe D2-12TR fits naturally into a wide range of automation roles:\u003c\/p\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eControlling conveyor motors and actuators in packaging lines\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eSwitching solenoid valves in fluid handling systems\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eDriving indicator lights and alarm horns on HMI panels\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eInterfacing PLCs with legacy AC-powered field devices\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eGeneral-purpose discrete output in process control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ: What PLC platforms is the D2-12TR compatible with?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e A: It is designed for use with the AutomationDirect DirectLOGIC DL205 modular PLC series. It is also compatible with the Do-more PLC platform. It does not plug directly into DL06, DL105, or other DirectLOGIC families without an appropriate base\/rack.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ: How many output points does the D2-12TR provide, and how are they grouped?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eA: The module provides 12 usable output points, divided into two isolated commons of 6 points each. It occupies 16 points in the I\/O map, with 4 unused addresses reserved by the system.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ: Can I mix AC and DC loads on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eA: Yes — each common is independently isolated, so you can run DC loads on one 6-point group and AC loads on the other. However, you should not mix AC and DC within the same common group, as the commons are shared within each group.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ: What is the maximum current this module can handle?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eA: Each individual output point supports up to 1.5A resistive load. The maximum current per common (shared across 6 points) is 3A. Exceeding these values risks tripping the onboard slow-blow fuses or damaging relay contacts.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ: What type of relay does the D2-12TR use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eA: The module uses Form A (SPST — Single Pole Single Throw) relay contacts. These are normally-open contacts that close when the output is energized.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ: Does it include a terminal block, and can wiring stay connected during module replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eA: Yes, the D2-12TR includes a removable D2-16IOCON terminal block. Because the terminal block detaches from the module body, field wiring can remain in place when swapping the module — a significant time saver during maintenance.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ: Are the fuses user-replaceable in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eA: Yes. The module uses two 4A slow-blow 5×20mm fuses that can be replaced by maintenance personnel without returning the module for service.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eQ: What does \"New in Box\" mean for this listing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eA: The unit is factory-new, unused, and in original manufacturer packaging — not refurbished, not tested-used. It is ready for immediate installation.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0635\/6516\/8701\/files\/D2-12TR_10_800x800_9d1ea873-dd03-4e75-9a88-7f81b5a47d5f.jpg?v=1772847276\" alt=\"\"\u003e\u003c\/p\u003e","brand":"topsdevice","offers":[{"title":"Default Title","offer_id":42781895688253,"sku":null,"price":114.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0635\/6516\/8701\/files\/D2-12TR.jpg?v=1773721971","url":"https:\/\/topsdevice.com\/products\/d2-12tr-plc-direct-koyo-relay-output-module-d212tr-new-in-box","provider":"topsdevice","version":"1.0","type":"link"}