{"product_id":"kso-g02-3ap-30-n-h3-new-original-daikin-ksog023ap30nh3-directional-control-valve","title":"KSO-G02-3AP-30-N-H3 New Original Daikin KSOG023AP30NH3 Directional Control Valve","description":"\u003ch2 data-section-id=\"kyjuiw\" data-start=\"627\" data-end=\"651\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp data-start=\"653\" data-end=\"1121\"\u003eThe \u003cstrong data-start=\"657\" data-end=\"726\"\u003eKSO-G02-3AP-30-N-H3 New Original Daikin Directional Control Valve\u003c\/strong\u003e is designed for hydraulic systems that require stable oil-flow switching, reliable pressure handling, and accurate actuator movement control. Also written as \u003cstrong data-start=\"885\" data-end=\"903\"\u003eKSOG023AP30NH3\u003c\/strong\u003e, this valve is commonly used in industrial hydraulic circuits where the direction of fluid flow must be controlled for cylinders, clamping units, machine tools, presses, automation equipment, and production machinery.\u003c\/p\u003e\n\u003cp data-start=\"1123\" data-end=\"1555\"\u003eThis Daikin directional valve helps control hydraulic movement by switching oil flow between circuit ports according to the solenoid command. In a hydraulic system, this type of valve is important for starting, stopping, or changing the movement direction of an actuator. It is suitable for equipment maintenance, valve replacement, hydraulic unit repair, and machine rebuilding where matching the original model number is critical.\u003c\/p\u003e\n\u003cp data-start=\"1557\" data-end=\"1949\"\u003eFor replacement use, the full model code \u003cstrong data-start=\"1598\" data-end=\"1621\"\u003eKSO-G02-3AP-30-N-H3\u003c\/strong\u003e should be checked carefully. The mounting interface, spool type, voltage code, connector style, hydraulic pressure range, and system oil type should match the existing valve before installation. Confirming these details helps reduce installation errors and ensures the valve works correctly with the original hydraulic circuit.\u003c\/p\u003e\n\u003ch2 data-section-id=\"tpkh8p\" data-start=\"1951\" data-end=\"1972\"\u003eKey Product Data\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKSO-G02-3AP-30-N-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompact Model Code\u003c\/td\u003e\n\u003ctd\u003eKSOG023AP30NH3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eDaikin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDirectional Control Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve Series\u003c\/td\u003e\n\u003ctd\u003eKSO-G02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Type\u003c\/td\u003e\n\u003ctd\u003eSolenoid directional control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eHydraulic flow direction control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Use\u003c\/td\u003e\n\u003ctd\u003eMachine tools, hydraulic power units, presses, automation systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Code\u003c\/td\u003e\n\u003ctd\u003eN, commonly listed as DC 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Check\u003c\/td\u003e\n\u003ctd\u003eMatch model code, coil voltage, port pattern, spool type and connector style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition Wording\u003c\/td\u003e\n\u003ctd\u003eNew Original\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 data-section-id=\"18p0o4p\" data-start=\"2539\" data-end=\"2557\"\u003eMain Features\u003c\/h2\u003e\n\u003cp data-start=\"2559\" data-end=\"2787\"\u003e\u003cstrong data-start=\"2559\" data-end=\"2597\"\u003eStable hydraulic direction control\u003c\/strong\u003e\u003cbr data-start=\"2597\" data-end=\"2600\"\u003eThe valve is used to control the direction of hydraulic oil flow, helping equipment perform forward, reverse, stop, clamp, release, or positioning actions depending on the circuit design.\u003c\/p\u003e\n\u003cp data-start=\"2789\" data-end=\"3008\"\u003e\u003cstrong data-start=\"2789\" data-end=\"2834\"\u003eSuitable for industrial hydraulic systems\u003c\/strong\u003e\u003cbr data-start=\"2834\" data-end=\"2837\"\u003eIt can be used in hydraulic power units, CNC machine tools, forming equipment, press machinery, clamping systems, automation lines, and other oil-pressure control systems.\u003c\/p\u003e\n\u003cp data-start=\"3010\" data-end=\"3235\"\u003e\u003cstrong data-start=\"3010\" data-end=\"3040\"\u003eModel-specific replacement\u003c\/strong\u003e\u003cbr data-start=\"3040\" data-end=\"3043\"\u003eThe complete code \u003cstrong data-start=\"3061\" data-end=\"3084\"\u003eKSO-G02-3AP-30-N-H3\u003c\/strong\u003e should be matched exactly when replacing an old valve. Small changes in spool type, voltage, connector style, or option code may affect compatibility.\u003c\/p\u003e\n\u003cp data-start=\"3237\" data-end=\"3403\"\u003e\u003cstrong data-start=\"3237\" data-end=\"3265\"\u003eCompact G02 valve format\u003c\/strong\u003e\u003cbr data-start=\"3265\" data-end=\"3268\"\u003eThe G02 size is commonly used in compact hydraulic circuits where reliable control and space-efficient valve installation are required.\u003c\/p\u003e\n\u003cp data-start=\"3405\" data-end=\"3638\"\u003e\u003cstrong data-start=\"3405\" data-end=\"3442\"\u003eUseful for maintenance and repair\u003c\/strong\u003e\u003cbr data-start=\"3442\" data-end=\"3445\"\u003eThis valve is suitable for restoring hydraulic circuit operation when the original directional valve has coil failure, spool sticking, leakage, unstable switching, or electrical control issues.\u003c\/p\u003e\n\u003ch2 data-section-id=\"uujcgr\" data-start=\"3640\" data-end=\"3662\"\u003eApplication Areas\u003c\/h2\u003e\n\u003cul data-start=\"3664\" data-end=\"3943\"\u003e\n\u003cli data-section-id=\"4zfj6o\" data-start=\"3664\" data-end=\"3697\"\u003eCNC machine hydraulic systems\u003c\/li\u003e\n\u003cli data-section-id=\"1rm65av\" data-start=\"3698\" data-end=\"3723\"\u003eHydraulic power units\u003c\/li\u003e\n\u003cli data-section-id=\"17rxtj2\" data-start=\"3724\" data-end=\"3746\"\u003eIndustrial presses\u003c\/li\u003e\n\u003cli data-section-id=\"qb73he\" data-start=\"3747\" data-end=\"3790\"\u003eInjection molding and forming equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1kiuurl\" data-start=\"3791\" data-end=\"3830\"\u003eClamping and positioning mechanisms\u003c\/li\u003e\n\u003cli data-section-id=\"18rzb0p\" data-start=\"3831\" data-end=\"3862\"\u003eAutomation production lines\u003c\/li\u003e\n\u003cli data-section-id=\"r9x0v2\" data-start=\"3863\" data-end=\"3902\"\u003eMachine tool repair and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"1392k5w\" data-start=\"3903\" data-end=\"3943\"\u003eHydraulic actuator direction control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"x9bttf\" data-start=\"3945\" data-end=\"3953\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"3955\" data-end=\"4148\"\u003e\u003cstrong data-start=\"3955\" data-end=\"4007\"\u003eQ1: What type of product is KSO-G02-3AP-30-N-H3?\u003c\/strong\u003e\u003cbr data-start=\"4007\" data-end=\"4010\"\u003eA1: It is a Daikin solenoid directional control valve used to control the direction of hydraulic oil flow in industrial hydraulic systems.\u003c\/p\u003e\n\u003cp data-start=\"4150\" data-end=\"4359\"\u003e\u003cstrong data-start=\"4150\" data-end=\"4209\"\u003eQ2: What should be checked before replacing this valve?\u003c\/strong\u003e\u003cbr data-start=\"4209\" data-end=\"4212\"\u003eA2: Check the full model number, voltage code, spool type, mounting pattern, connector style, hydraulic oil type, and system pressure requirements.\u003c\/p\u003e\n\u003cp data-start=\"4361\" data-end=\"4554\"\u003e\u003cstrong data-start=\"4361\" data-end=\"4402\"\u003eQ3: Is KSOG023AP30NH3 the same model?\u003c\/strong\u003e\u003cbr data-start=\"4402\" data-end=\"4405\"\u003eA3: Yes, KSOG023AP30NH3 is a compact writing style of KSO-G02-3AP-30-N-H3, but the full marked code should still be confirmed on the valve nameplate.\u003c\/p\u003e\n\u003cp data-start=\"4556\" data-end=\"4727\"\u003e\u003cstrong data-start=\"4556\" data-end=\"4598\"\u003eQ4: Where is this valve commonly used?\u003c\/strong\u003e\u003cbr data-start=\"4598\" data-end=\"4601\"\u003eA4: It is commonly used in hydraulic power units, machine tools, presses, automation equipment, and actuator control circuits.\u003c\/p\u003e\n\u003cp data-start=\"4729\" data-end=\"4962\"\u003e\u003cstrong data-start=\"4729\" data-end=\"4781\"\u003eQ5: Why is the full Daikin model code important?\u003c\/strong\u003e\u003cbr data-start=\"4781\" data-end=\"4784\"\u003eA5: The full code identifies the valve series, spool configuration, voltage, design number, and options. Matching the complete code helps avoid installation and control problems.\u003c\/p\u003e","brand":"topsdevice","offers":[{"title":"Default Title","offer_id":42741224243261,"sku":null,"price":43.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0635\/6516\/8701\/files\/KSO-G02-3AP-30-N-H3.jpg?v=1777259827","url":"https:\/\/topsdevice.com\/products\/kso-g02-3ap-30-n-h3-new-original-daikin-ksog023ap30nh3-directional-control-valve","provider":"topsdevice","version":"1.0","type":"link"}